Ukugunyazwa | I-IEC62930/EN50618 |
I-voltage yokulinganisa | I-DC1500V |
I-voltage yokuhlola | I-AC 6.5KV, 50Hz 5min |
Izinga lokushisa lokusebenza | -40 ~ 90℃ |
Ukushisa Okuphezulu Kokuziphatha | 120 ℃ |
Izinga lokushisa lesifunda esifushane | 250℃ 5S |
Irediyasi egobayo | 6×D |
Isikhathi Sokuphila | ≥25 iminyaka |
I-Cross Section(mm2) | Ukwakha(No./mm±0.01) | I-DIA. (mm) | Ukuqina kwe-Insulation(mm) | Ubukhulu bejakhethi(mm) | Ikhebula OD.(mm±0.2) |
1×2.5 | 34/0.285 | 2.04 | 0.7 | 0.8 | 5.2 |
1×4 | 56/0.285 | 2.60 | 0.7 | 0.8 | 5.8 |
1x6 | 84/0.285 | 3.20 | 0.7 | 0.8 | 6.5 |
1×10 | 7/1.35 | 3.80 | 0.8 | 0.8 | 7.3 |
1×16 | 7/1.7 | 4.80 | 0.9 | 0.9 | 8.7 |
1x25 | 7/2.14 | 6.00 | 1.0 | 1.0 | 10.5 |
1x35 | 7/2.49 | 7.00 | 1.1 | 1.1 | 11.8 |
Iphakheji REF
| Ngaphandle Spool
| Nge Spool
| ||
I-MPQ (m) (4mm2) | 250m | 1000m | 3000m | 6000m |
Iphalethi eyodwa (4mm2) | 14,400m | 30,000m | 18,000m | 12,000m |
20GP Conumthungi | 300,000m okwe 4mm2 | |||
200,000m okwe 6mm2 |
Isigaba esiphambanayo (mm²) | I-Conductor Max. Ukumelana @20℃ (Ω/km) | I-Insulation Min. Ukumelana @20℃ (MΩ · km) | I-Insulation Min. Ukumelana @ 90℃ (MΩ · km) | |
1×2.5 | 8.21 | 862 | 0.862 | |
1×4 | 5.09 | 709 | 0.709 | |
1x6 | 3.39 | 610 | 0.610 | |
1×10 | 1.95 | 489 | 0.489 | |
1×16 | 1.24 | 395 | 0.395 | |
1x25 | 0.795 | 393 | 0.393 | |
1x35 | 0.565 | 335 | 0.335 |
Ukumelana ne-insulation @20℃ | ≥ 709 MΩ · Km |
Ukumelana ne-insulation @90℃ | ≥ 0.709 MΩ · Km |
Ukumelana nobuso be-sheath | ≥109Ω |
Ukuhlolwa kwe-voltage yekhebula eqediwe | I-AC 6.5KV 5min, Akukho ukuphumula |
Ukuhlolwa kwe-DC Voltage yokufakelwa | 900V, 240h(85℃, 3%Nacl) Akukho ukuphumula |
Amandla okuqina we-insulation | ≥10.3Mpa |
Amandla aqinile we-sheath | ≥10.3Mpa |
ukwelulwa kwe-sheath | ≥125% |
Ukumelana nokuncipha | ≤2% |
Ukumelana ne-Acid ne-alkali | EN60811-404 |
Ukumelana ne-ozone | EN60811-403/EN50396-8.1.3 |
Ukumelana ne-UV | EN 50289-4-17 |
Amandla okungena anamandla | I-EN 50618-Annex D |
(-40℃,16h) Ukuvunguza ekushiseni okuphansi | I-EN 60811-504 |
( -40℃, 16h) Umthelela ekushiseni okuphansi | EN 60811-506 |
Ukusebenza komlilo | I-IEC60332-1-2 kanye ne-UL VW-1 |
Okuqukethwe kwe-Cland Br | I-EN 50618 |
Ukuhlolwa kokubekezelela okushisayo | EN60216-1,EN60216-2, TI120 |
I-Solar DC single core copper cable iyikhebula elakhelwe ngokukhethekile i-DC yokuphehla amandla elanga. Yenziwe ngethusi lekhwalithi ephezulu, le ntambo ilungele ukudlulisa amandla ngendlela ephumelelayo ebangeni elide. Ilungele ukuxhuma amaphaneli elanga, ama-inverter, nezinye izakhi ohlelweni lwamandla elanga.
4MM2, 6MM2, kanye 10MM2 ukucaciswa okuvame ukusetshenziswa kakhulu kwezintambo zethusi eziwumgogodla owodwa we-solar DC. Ubukhulu bekhebula elidingekayo buncike ekuphumeni kwamandla kwephaneli yelanga kanye nebanga elidingekayo ukuze uxhumeke kwezinye izingxenye. Usayizi we-4MM2 ulungele amasistimu elanga amancane naphakathi, kuyilapho ubukhulu be-6MM2 kanye ne-10MM2 bufaneleka kakhulu kumasistimu amakhulu kagesi welanga.
Inzuzo yokusebenzisa izintambo zethusi zezinhlelo zelanga ukuthi ithusi liyinto eqhuba kakhulu eqhuba ugesi kahle kakhulu. I-Copper futhi inokumelana nokugqwala okuhle kakhulu, okuyenza ilungele ukusetshenziswa ngaphandle lapho ingase ichayeke khona esimweni sezulu esibi.
Ikhebula le-solar DC single-core copper alikwazi ukumelana nokukhanya kwelanga, i-flame retardant, futhi iphephile ukuthi isetshenziswe ezindaweni ezingaphandle. Ukufakwa kwamakhebula kuphinde kwenziwe ngezinto ezikhethekile ezingazweli kwi-UV, eziqinisekisa ukuthi ziphila isikhathi eside futhi zithembekile.
Lapho ukhetha ikhebula le-solar DC eliwumgogodla owodwa, kubalulekile ukukhetha ikhebula elithobela izindinganiso zikazwelonke ezisebenzayo futhi elinezitifiketi ezidingekayo. Lokhu kuqinisekisa ukuthi ukusetshenziswa kwezintambo ezinhlelweni zokuphehla amandla elanga kuphephile futhi kuthembekile.
Ukufingqa, izintambo zethusi eziwumgogodla we-solar DC ziyingxenye ebalulekile yanoma yiluphi uhlelo lokuphehla amandla elanga. Yenziwe ngethusi lekhwalithi ephezulu ukuze kuqinisekiswe ukusebenza kahle okukhulu, ikhebula alikwazi ukumelana nelanga futhi liyamelana nelangabi ukuze lisetshenziswe ngokuphephile ezindaweni zangaphandle. Nikeza 4MM2, 6MM2, 10MM2 osayizi abathathu ukuze bavumelane nosayizi abahlukahlukene namandla okukhipha amandla wezinhlelo zokuphehla amandla elanga.